Rafters are 2x4, 12/12 slope, as well as roof is complex with intersecting ridge traces, valleys and dormers. (Your house at first had a cedar roof. The deck is the normal spaced fir planks.) On account of the construction, there is almost no chance of receiving suitable air consumption through soffit vents. (Along with the structure difficulties, you will discover troubles due to the fact the many spaces amongst rafters wherever they meet up with the highest plate had been bricked in, evidently at time of construction). Correct regular stream-via underdeck roof air flow are going to be hard. After we first appeared into this venture, the developing inspector asked us to even now use vent channels (low-priced polystrene was Alright) to seize whatever air flow we could.

A. You will find a code necessity for a vapor retarder in a few varieties of assemblies, but there is no requirement to get a vapor barrier. Your layer of rigid foam is by now a vapor retarder. No additional vapor retarding layer needs to be installed.

A. If the intention is to put in a great air barrier, then drywall is certainly enough, as long while you seal all penetrations to prevent air leakage. For additional on putting in drywall in an airtight fashion, see Airtight Drywall.

Ought to I take advantage of airtight baffles or not, I do not see a method to have humidity escaping in a very assembly with airtight baffles, fiberglass and xps on the inside, regardless of the the dew stage might be inside this assembly And perhaps make condensation that are unable to evaporate without ventilation.

Q. "I am wondering if I really should furr out the rafters to obtain the desired thickness of spray foam, or if installing a few inches of polyiso foam for the underside on the rafters, once the spray foam, could operate?"

  You will need a roof maintenance contractor that can help repair your roof!  Neighborhood roofing contractors is going to be able for making your residential or commercial roof new again. The best news is, roofing fix is often inexpensive.

Be sure to set up insulation that presents at least the least code prerequisite for ceiling R-price. Insulation that exceeds the bare minimum code necessity is a lot better.

If a developing inspector insists that you put in some sort of inside “vapor barrier,” you could normally install a wise vapor retarder like roofing company austin tx MemBrain to satisfy your inspector.

Whilst vented roof assemblies are made to dry to the outside, unvented roof assemblies are built to dry to the interior. That’s why an unvented roof assembly should hardly ever include things like inside polyethylene.

While roof air flow will help dry out moist roof sheathing, it’s necessary to Restrict the movement of h2o vapor escaping within the household so that the roof sheathing by no means will get moist in the first place.

The majority of the knowledge I run throughout seems to be in the cellulose business that statements wind-wash is a giant dilemma with fiberglass; and from the fiberglass industry which asserts that the cellulose group overstates The difficulty and that into the extent wind-wash happens it is admittedly inconsequential.

In order for you a vapor-permeable material that continues to be an air barrier, pick fiberboard sheathing. But use caulk around the perimeter, and tape within the seams, To this article make sure that the fabric is set up in an airtight method.

Finally, I kow the recessed lighting is Awful, but what can I do whether it is previously installed? With one of the lights I adjusted it in excess of to your pendant light which lessened the warmth near the roof although the air barrier is still a challenge.

I've crafted log properties inside the Yukon Territory in northern Canada for thirty several years. Most log structures have cathedral ceilings. The vast majority of roofs We have now designed are as follows (from The underside up): log purloins, nominal 2" (2x6) t&g decking, 6mil poly, 1 one/2" extruded polystyrene foam, 2x10 rafters on 24" centers, 7" fiberglass, 2x4 strapping, 7/sixteen OSB, underlayment (15 lb paper, 30lb felt, or now we'd even use ice and h2o shield). There would be about an inch of air space down below the strapping for equally vertical and horizontal air flow. All roofs are vented with strip vents in the eaves and vents during the soffit (2x6 t&g) at the height at both ends. I might disagree that venting is not essential should you halt the airflow on The nice and cozy facet, for two good reasons. To start with it's very hard to prevent all airflow, Specifically with standard common procedures (ie chimney and plumbing vent penetrations through the roof) Now we have a number of strategies produced through the years to seal the vb in the eaves and gables, but there remain nail penetrations throughout the vb. In general Going Here I feel we had quite tight seals but one particular could under no circumstances say airtight.